Previous
Epochem_109_Corrosion_Inhibitor_5Ltr

Epochem 109 Corrosion Inhibitor 5Ltr

16,125.00
Next

Epochem 502 Heavy Duty Degreaser and Industrial Cleaner, 25Liters

25,262.00
Epochem Heavy Duty Degreaser
Epocool Corrosion Inhibitor Coolant

Epocool 2000 Corrosion Inhibitor Coolant 25L

48,375.00

Epocool 2000 Corrosion Inhibitor Coolant 25L

48,375.00

Epocool 2000 Corrosion Inhibitors coolant provides complete protection of cooling system components. This product do not contain borates, phosphate, amines and silicates and are available in ethylene glycol based fluid.

Hurry up! Flash Sale Ends Soon!
00
DAYS
00
HOURS
00
MINS
00
SECS
Add to Wishlist
Add to Wishlist

Description

Epocool 2000 Corrosion Inhibitor Coolant 25L

Hellog Energy is a supplier of Epochem brand of Cleaning and maintenance chemicals in Nigeria. Our Epocool 2000 Corrosion Inhibitors coolant are a series of extended life industrial coolant/antifreeze and heat transfer fluids formulated for stationary equipment applications are already pre-diluted. These products are based on a unique extended life carboxylate inhibitor system and nitrite/molybdate as secondary inhibitors. Epocool 2000 Corrosion Inhibitors coolant provides complete protection of cooling system components. This product do not contain borates, phosphate, amines and silicates and are available in ethylene glycol based fluid.

APPLICATIONS OF EPOCOOL 2000 COOLANT

• Stationary engines used in natural gas processing, irrigation, power generation, marine applications, oilfield operations and portable air compressors

• Heat transfer applications such as line heaters, snow melting systems

• Unique applications such as coolants in air conditioning units

• On-road/off road heavy-duty diesel engine applications

• Glycol based products can be used where toxicity is a concern

• Nitrite free product is recommended for on-road/off road and industrial applications

BENEFITS

• Longer service life with no inhibitor additions required

• Protects all industrial cooling system metals including brass, copper, solder, steel, cast iron and aluminum

• Contains no silicates, phosphates, borates or amines

• Low dissolved solids formula prevents formation of deposits

• Phosphate free formula helps prevent hard water scale formation

• Silicate free technology maintains good as new heat transfer and prevents formation of silicate gels during use and storage

• 100% biodegradable in its unused form

• Available as ethylene glycol based fluids

Technical Specification

TYPICAL PROPERTIES                                    PRE-DILUTE

Appearance                                                                  Clear Liquid

Color                                                                              Blue-green

Specific Gravity                                                           1.06

Freezing point 50%(Aqueous soln)                        N/A

pH                                                                                  8.3

Freezing point                                                             34

Alkalinity                                                                      3.0

Silicate(%)                                                                    None

Boil over protection                                                   1290C

PROCEDURES FOR USE

• Allow cooling system to cool thoroughly Drain traditional coolant from cooling system.

• Dispose of all coolant according to all laws and regulations.

• Fill cooling system with clean water and circulate system until normal operating temperatures are reached.

• Circulate system for 15 to 30 minutes after reaching normal operating temperatures.

• Check system for any leaks and replace any worn materials.

• Drain the water from the cooling system completely

• Dispose of all re-circulated water according to all laws and regulations. Water that remains in cooling system will affect the freeze point of new coolant when added.

• Re-filling the cooling system, If using Epocool 2000 Corrosion Inhibitors coolant. Fill the cooling system about 9/10 full with Epocool Pre-diluted 50/50. Circulate system until normal operating temperature is reached. Test freeze point and adjust to between -15ºF and -62ºF. The optimal freeze point is -34ºF.

• For over concentrated systems use water to make freeze point more positive. Circulated system after freeze point has been adjusted.

MAINTENANCE

• Check coolant level regularly. If systems are prone to leaking more frequent checking of the cooling system is recommended to maintain proper fluid levels. Top up as required with Epocool 2000 Corrosion Inhibitors Coolant.

• Coolant levels should be maintained at proper levels to insure correct cooling system operation and avoid headspace corrosion.

• For systems using ethylene glycol check freeze point at least twice per year using a refractometer and adjust to between -15ºF and -62ºF. Optimum freeze point is -34ºF.

Contact us for product availability.

 

Download TECHNICAL DATA SHEET.

Reviews

There are no reviews yet.

Be the first to review “Epocool 2000 Corrosion Inhibitor Coolant 25L”

Your email address will not be published. Required fields are marked *

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping